Hydraulic Power Supplies
ANCO provides hydraulic power supplies in four flow rate sizes for use in hydraulic testing systems. We can deliver these power supplies with constant or variable volume pumps. All power supplies provide for local and remote start and maintain cooling flow through the heat exchanger during periods of no flow to the test system. The control systems shut down on over temperature, over current, and low oil level. All systems have water saver valves. We also offer electronically sequenced pilot/main loops and electronically monitored oil filters options.
Parameter |
Model 21.01A |
Model 21.01B |
Model 21.02A |
Model 21.02B |
Flow capacity at 21 MPa (3000 psi) |
|
|
|
|
At 60 Hz |
58.1 L/min (15 GPM) |
116 L/min (30 GPM) |
232 L/min (60 GPM) |
697 L/min (180 GPM) |
At 50 Hz |
48.4 L/min (12 GPM) |
97 L/min (25 GPM) |
193 L/min (50 GPM) |
581 L/min (150 GPM) |
Pump Motor |
|
|
|
|
Motor Type |
Totally enclosed, fan cooled |
Totally enclosed, fan cooled |
Totally enclosed, fan cooled (2) |
Totally enclosed, fan cooled (3) |
Rating |
22.6 kW (30 hp) |
56.5 kW (75 hp) |
56.5 kW (75hp) |
94.25 kW (125 hp) |
Operating voltage |
460V 50-60 Hz |
460V 50-60 Hz |
460V 50-60 Hz |
460V 50-60 Hz |
Continuous amps |
|
|
|
|
Starter type |
Line voltage std |
Line voltage std |
Line voltage std |
Line voltage std |
Solenoid control amps (from local 24 VDC power supply) |
|
|
|
|
Water requirements |
|
|
|
|
Water hose (I.D.) |
|
|
|
|
Cooling water flow |
Varies Contact ANCO |
Varies Contact ANCO |
Varies Contact ANCO |
Varies Contact ANCO |
Water pressure differential at the heat exchanger |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
0.17 MPa (25 psi) |
Maximum allowable input water pressure |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
0.8 MPa (120 psi) |
Maximum cooling water heat load |
17000 kcal/hr (66300 Btu/hr) |
43000 kcal/hr (167000 Btu/hr) |
86000 kcal/hr (335000 Btu/hr) |
210000 kcal/hr (819000 Btu/hr) |
Atmospheric heat load1 |
2300 kcal/hr (9000 Btu/hr) |
5800 kcal/hr (22500 Btu/hr) |
11600 kcal/hr (45000 Btu/hr) |
28000 kcal/hr (110000 Btu/hr) |
Maximum ambient operating temperature |
|
|
|
|
Minimum ambient operating temperature |
|
|
|
|
Noise rating, dBA at approx. |
71 |
73 |
74 |
82 |
Reservoir capacity |
( |
( |
( |
( |
Hydraulic fluid |
|
|
|
|
Standard |
Mobil DTE 25 |
Mobil DTE 25 |
Mobile DTE 25 |
Mobil DTE 25 |
Alternate |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
Shell Tellus 46 AW |
Hydraulic fluid filtration (microns) |
|
|
|
|
Nominal |
0.45 |
0.45 |
0.45 |
0.45 |
Absolute (Beta3 = 200) |
3.0 |
3.0 |
3.0 |
3.0 |
Max. fluid operating temperature |
|
|
|
|
Hydraulic fluid hose connection |
|
|
|
|
Pressure and return (two connections each, 37 deg. flare)3 |
-12 |
-16 |
-20 |
-32 |
Drain (three connections, 37deg. (flare) |
-8 -6 -6 |
-12 -8 -8 |
-12 -8 -8 |
-16 -12 -12 |
Height (without casters) |
( |
( |
( |
( |
Length |
( |
( |
( |
( |
Width |
( |
( |
( |
( |
Weight without fluid (uncrated) |
|
|
|
|